En ny major-version av Clavister cOS 10, 10.10.00, med bland annat stöd för Clavisters nya hårdvarumodeller Lynx L8, Wolf W3 och W5, och ett flertal intressanta nya funktioner har släppts.
Kontakta Certezza Support vid frågor,
E-post: support@certezza.net
Telefon: 08-791 92 02
Nya funktioner
- Application Control Rule Sets
- User Identity Awareness
- Virtual Routing support for SSL VPN
- Web Content Filtering for HTTPS
- L2TPv3 server support
- Routing support in SSL VPN Client
Buggfixar i cOS Core 10.10.00
Utöver ovan nämnda nya funktioner innehåller cOS 10.10.00 även en lång rad buggfixar för problem som upptäckts i tidigare versioner:
| ID |
Description |
| COP-10409 |
SSL VPN sessions could cause erroneous behavior if the Security Gateway reconfigured while sessions were being authenticated. |
| COP-10703 |
Unexpected behavior could occur due to memory management issues associated with LDAP authentication. |
| COP-10753 |
A configuration with the now obsolete selection of Log And Event Receiver category '36 (USAGE)' would send out empty log data. The configuration is now silently updated to exclude this category. |
| COP-10862 |
The realm string for HTTP basic authentication was not optional like in cOS Core 8.x versions. |
| COP-10995 |
The 'close' button for dialogs on an IPPolicy was confusing with regards to its use and has been removed. |
| COP-10997 |
Double clicking a Comment group in the WebUI to start editing the group was not possible. |
| COP-11012 |
Pressing enter in a textbox when adding a new object in a dialog triggered a faulty window behavior. |
| COP-11013 |
Cloning rules with a reference to an address in a folder failed because of a missing path. |
| COP-11016 |
The clone option was enabled for disabled objects which resulted in a blank clone. The clone option has been removed for disabled or deleted objects. |
| COP-11064 |
The HWM monitoring status page was missing from the WebUI. |
| COP-11065 |
There were no notifications in the WebUI when the UTM services subscriptions were about to expire. |
| COP-11089 |
The link status of the ge-interfaces on the SG60 model would disappear shortly during the reconfigure process. |
| COP-11124 |
Upgrading a Security Gateway which had a configuration that was using log message exceptions for the category 36 'Usage' could lead to an unexpected reboot. All references to these are now removed correctly since they have become obsolete. |
| COP-11248 |
Removing all switch routes from a routing table other than the main routing table could sometimes result in unexpected behavior. |
| COP-11258 |
The TLS protocol, which was incorrectly available for selection on an IPPolicy has been removed. |
Release Notes för versionen hittas här: https://www.clavister.com/Documents/products-and-services/cos-core/clavister-cos-core-10-10/clavister-prd-clavister-cos-core-10-10-release-notes-gb.pdf
Observera att cOS Core 10.10.00 inte är kompatibelt med InControl-versioner tidigare än 1.30.01!